Originally Posted by Silvercreek Farmer View Post
So I have isolated every wire and get the same result on each one, weak current. The fence is spotless. The only thing I can think of is that my corner post insulators are bad. I have these type Electric fence Problems - Homesteading Questions and perhaps the wires have rubbed through the inside of them. I think I am going to try furring them out with some sort of rubber and see if that helps...
I tried those but they failed quite often. Didn't last very long at all.
Reply With Quote
  #22  
Old 01/23/12, 04:13 PM
Living the dream.
 
Join Date: Oct 2005
Location: Morganton, NC
Posts: 1,982
From Parmaks website:

DO replace ground rods every two years or so. The ground rods will rust under ground and over time will no longer be a good ground.

I have set up my second wire up as a ground with my first and third hot all about 5 inches from each other. Hopefully this will do the trick.
Reply With Quote
  #23  
Old 02/01/12, 11:22 AM
Living the dream.
 
Join Date: Oct 2005
Location: Morganton, NC
Posts: 1,982
Just ordered a new Parmak SE4...
Reply With Quote
  #24  
Old 03/02/12, 05:53 AM
 
Join Date: Feb 2005
Location: NC
Posts: 856
I just had a phone call from Brookside Fence Charger repair, I have never ever had such incredible customer service....he is going to rebuild my bad charger....a solar model, Patriot something....he is rebuilding it with Parmak guts....and offering a warranty...this will cost less than a new portable short term use charger.....he highly recommends Parmak and he seems to be very skilled at reworking almost any issue that might come up with any brand of charger...so I will for sure be keeping his number in my resource book...it is a pleasure to do business with folks like this.....
Reply With Quote
  #25  
Old 03/02/12, 06:18 AM
 
Join Date: Aug 2011
Location: Nevada
Posts: 217
My first guess, it is the ground rods. Corrosion will cause them to loose contact. dry soil will also.
Reply With Quote
  #26  
Old 03/02/12, 07:11 AM
solidwoods's Avatar
Ret. US Army
 
Join Date: Dec 2005
Location: Tennessee
Posts: 870
I'd disconnect all strands but 1 and test. Then rehook up each strand 1 at a time and check them. If one of the strands is grounding it should show it.
jim
__________________
If an elected official is in charge of a budget and that budget is not balanced, the elected official is not eligible for re-election until the budget is balanced.
Be a leader not a follower
Reply With Quote
  #27  
Old 03/02/12, 08:35 AM
monkeybackfarm's Avatar  
Join Date: Apr 2010
Location: Ayden,NC
Posts: 75
I use 3, 8' copper ground rods plus a 10' galvanized 3/4 water pipe.I get the max from my parmak even in dry weather. I have learned not to trust plastic insulators as some companies use cheap polmers which can short through to the nail or screw. Black widow is a trusted company along with the round porcline insulators.
Reply With Quote
  #28  
Old 03/02/12, 09:30 AM
Banned
 
Join Date: Oct 2006
Posts: 12,448
I use one ground rod. The length depends on how hard it is to put it in.
I use every other wire as the ground. Works good and I get the max between the wires from my charger.
Reply With Quote
Reply




Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



All times are GMT -5. The time now is 02:21 AM.
Contact Us - Homesteading Today - Archive - Privacy Statement - Top - ©Carbon Media Group Agriculture